Collar Ties, Rafter Ties, Purlins and Braces JWK Inspections

Collar Ties, Rafter Ties, Purlins and Braces JWK Inspections

Collar Ties, Rafter Ties, Purlins and Braces

Submitted by JoeKeresztury on Sun, 03/14/2010 — 04:34.

In the roof frame of a home, collar ties and rafter ties are commonly confused for one another. Both are horizontal framing members that serve different purposes and are both important to a properly framed roof.

Collar ties are connections between rafters at the upper one third of the roof area just below the ridge and are required at every other rafter of a 24 on center spacing and every third rafter with 16 on center spacing. Metal Brackets or Straps can be an acceptable alternative in lieu of the more common use of the wood framed collar ties. Collar ties prevent rafter separation and uplift. Contrary to belief collar ties do not prevent wall separation, they are intended to prevent rafter/roof uplift. Collar ties as per current IRC code are required to be at least 1×4(nominal) material but are most commonly at least 2×4’s. This is on a conventional stick frame (non truss) structure, as trusses do not require collar ties from a framing material as they are tied together with metal plates / gussets. Also, an engineered truss roof frame does not ordinarilly have a ridge.

Rafter ties are installed as low as possible as they are required to be in the lower third of the roof frame area to prevent exterior walls from spreading. Spreading walls will create a sagging roof. Ceiling joists serve as Rafter ties when they are running the same direction as the rafters and are tied together with them at the exterior wall. When the ceiling joists are running perpendicular with the rafters then rafter ties are run above the joists in the direction of the rafters and are fastened to them. Rafter ties when not also serving as ceiling joists are required to be at least a 2×4 material and should be on edge. These rafter ties running perpendicular above the joists need to be a maximum of 48 on center apart, which would be every other rafter on a 24 o.c. spacing or every three rafters on a 16 on center spacing. Rafter ties (not serving as ceiling joists) that are running above and perpendicular with the joists can sit on the joists and also be fastened to them thus also serving as strong backs to help prevent ceiling joists from twisting and sagging.

Purlins on a roof frame serve the purpose of preventing rafters from being over spanned and sagging. Purlins are placed under rafters in a perpendicular position on edge (not flat). The purlins are supported by vertical or slightly angled bracing. The braces (struts or kickers) should be within every 4′ and should not be at a greater than a 45 degree angle towards the roof slope (lower side).

In this image you can see the collar ties as required. Ceiling Joists serving as rafter ties are shown in both images. Purlins are present for rafter support.

An important notation is that the purlin braces are off of walls as needed. Bracing can not be off of the ceiling (joist) frame.

Left Image- Bowed exterior wall due to missing Rafter Ties.

Image at right shows a sagging Roof Ridge as a result of the missing Rafter Ties and the bowed out exterior wall.

In this photo, the collar ties as required are missing, the purlins with bracing are properly installed. Ceiling joists serving as rafter ties as seen in above image as needed were verified at the inspection of the San Antonio home seen in the photo.

Purlin braces or any other roof braces, ridge braces, hip rafter bracing along with valley bracing must not be supported off the ceiling joists. Bracing must be installed off of walls or beams. Larger joist framing materials, for instance 2×10 or 2×12’s can be doubled or tripled up with plywood in between and glued to create a flush beam to brace off of as long as it is not over spanned, so as to prevent deflection. Over a long span room area not having anything to brace the roof off of a floating beam can be added above the ceiling joists to brace off of. When ever beams are added and are bearing on a wall solid 2 x 4’s should be filled in under the beam in the wall frame to match the width of that beam. A triple 2 x 12 beam should have at least 3 solid 2 x 4’s underneath it, not just below the double top plate but also above it if the beam is not resting on the top plates. These beams at their ends should be blocked / braced with framing pockets to prevent twisting and turning. A dropped (exposed) beam is the third alternative when space limitations prohibit the flush beam or raised/ floating beam from being added for roof support bracing.

By Joe Keresztury, San Antonio Home Inspector and New Home Construction Specialist